VPI Non-Encapsulated Dry-Type Transformer

VPI Non-Encapsulated Dry-Type Transformer is configured to the purchaser's network, load and site requirements. The typical range below is for product-page reference; final guaranteed values are confirmed in the approved technical schedule.

RATED VOLTAGE
Up to 15 kV typical

RATED CAPACITY
50-5,000 kVA

STANDARDS BASIS
IEC 60076-11 or IEEE C57.12.01

TYPICAL APPLICATION
Industrial facilities, commercial buildings and controlled indoor environments.



  • Overview
  • Recommended Products

Appurtenance

  • Open ventilated or enclosed construction.
  • copper or aluminum windings.
  • harmonic-duty and low-noise options.

Inquiry

Please provide the following information so the product selection and quotation can be prepared accurately:

  • Rated power, voltage ratio, frequency and vector group.
  • Cast-resin or VPI construction, winding material and enclosure IP.
  • Temperature-rise, harmonic duty, ventilation and noise requirements.
  • Indoor conditions, altitude, fire/environment class and standard.

Overview

General Product Overview

The VPI non-encapsulated dry-type transformer uses vacuum-pressure impregnation to provide a practical insulation system for indoor distribution and industrial loads. The design can be adapted for ventilation, enclosure, harmonic duty and project-specific temperature-rise requirements.

Main Technical Specifications

Parameter

Typical range / configuration basis

Rated voltage

Up to 15 kV typical

Rated capacity

50-5,000 kVA

Frequency

50 Hz or 60 Hz; utility-specific where applicable

Standards basis

IEC 60076-11 or IEEE C57.12.01

Cooling

AN or AF

Winding material

Copper or aluminum according to the approved design

Enclosure

Open construction or project-specific IP enclosure

Temperature monitoring

PT100 sensors and controller; fan control where applicable

Insulation and Enclosure Options

The insulation system is selected for the installation environment and connected load. Enclosure ventilation, conductor material, temperature sensors, fan control and harmonic capability are coordinated before the outline drawing is approved.

  • Open ventilated or enclosed construction.
  • copper or aluminum windings.
  • harmonic-duty and low-noise options.

Main Applications

Industrial facilities, commercial buildings and controlled indoor environments.

  • Buildings, hospitals, data centers and transport infrastructure.
  • Industrial plants and indoor distribution rooms.
  • Installations prioritizing fire performance and low maintenance.

Engineering Support

Apex supports requirement review, product selection, drawing and interface coordination, manufacturing follow-up, inspection/test-document coordination, export packing and delivery planning. The final scope is defined in the quotation and approved technical agreement.

Recommended Products

Cast Resin Dry-Type Transformer | KYN28 Metal-Clad MV Switchgear | GCS Withdrawable LV Switchgear

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/whatsapp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/whatsapp
Name
Company Name
Message
0/1000