+86-13911506505
All Categories

High-Voltage GIS Switchgear

High-Voltage GIS Switchgear is configured to the purchaser's network, load and site requirements. The typical range below is for product-page reference; final guaranteed values are confirmed in the approved technical schedule.

RATED VOLTAGE
72.5-252 kV

RATED CAPACITY
Bus current and fault rating are project-specific

STANDARDS BASIS
IEC 62271 series

TYPICAL APPLICATION
Transmission substations, renewable-energy grid connection and space-constrained sites.

  • Overview
  • Recommended Products

Appurtenance

  • Line, transformer, bus-coupler and metering bays.
  • local control cabinet.
  • protection, monitoring and SCADA interfaces.

Inquiry

Please provide the following information so the product selection and quotation can be prepared accurately:

  • Single-line diagram, rated voltage/current and frequency.
  • Short-circuit level, bus arrangement and feeder schedule.
  • Protection relay, metering, interlocking and communication requirements.
  • Internal-arc/IP requirement, cable interface, auxiliary supply and standard.

Overview

General Product Overview

High-voltage GIS provides compact, enclosed switching bays for transmission-level substations. Bay arrangement, rated current, short-circuit duty, insulation level, gas compartments, protection and control interfaces are confirmed from the single-line diagram and utility requirements.

Main Technical Specifications

Parameter

Typical range / configuration basis

Rated voltage

72.5-252 kV

Rated capacity

Bus current and fault rating are project-specific

Frequency

50 Hz or 60 Hz; utility-specific where applicable

Standards basis

IEC 62271 series

Rated current

Selected from the approved load schedule and bus arrangement

Short-circuit duty

Confirmed from the system fault study

Protection

Relay, metering, interlocking and trip logic by single-line diagram

Communication

Hardwired or digital interfaces to the project SCADA/BMS

Protection and Control Configuration

The equipment lineup is built from the single-line diagram, fault study and feeder schedule. Breaker ratings, busbar system, protection logic, metering, interlocks, cable compartments and communication interfaces are confirmed in the approved drawings.

  • Line, transformer, bus-coupler and metering bays.
  • local control cabinet.
  • protection, monitoring and SCADA interfaces.

Main Applications

Transmission substations, renewable-energy grid connection and space-constrained sites.

  • Utility transmission and distribution substations.
  • Industrial and infrastructure power systems.
  • Renewable-energy and commercial distribution.

Engineering Support

Apex supports requirement review, product selection, drawing and interface coordination, manufacturing follow-up, inspection/test-document coordination, export packing and delivery planning. The final scope is defined in the quotation and approved technical agreement.

Recommended Products

KYN28 Metal-Clad MV Switchgear | Medium-Voltage Ring Main Unit | GCS Withdrawable LV Switchgear

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/whatsapp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/whatsapp
Name
Company Name
Message
0/1000