+86-13911506505
All Categories

Rectifier and Phase-Shifting Transformer

Rectifier and Phase-Shifting Transformer is configured to the purchaser's network, load and site requirements. The typical range below is for product-page reference; final guaranteed values are confirmed in the approved technical schedule.

RATED VOLTAGE
Up to 35 kV input typical

RATED CAPACITY
100 kVA-50 MVA

STANDARDS BASIS
IEC 61378 and project requirements

TYPICAL APPLICATION
Electrolysis, metal processing, industrial drives and rectifier systems.

  • Overview
  • Recommended Products

Appurtenance

  • Six-, twelve- or multi-pulse arrangements.
  • phase-shifting windings.
  • interphase options.
  • oil-immersed or dry-type construction.

Inquiry

Please provide the following information so the product selection and quotation can be prepared accurately:

  • Input/output voltage, capacity, frequency and connected load.
  • Load waveform, harmonic spectrum, duty cycle and overload requirement.
  • Insulation, enclosure, cooling, protection and certification requirements.
  • Installation environment, dimensions and project documentation.

Overview

General Product Overview

The rectifier and phase-shifting transformer is engineered together with the rectifier topology and DC process duty. Pulse number, phase shift, harmonic current, cyclic loading, short-circuit duty and cooling are reviewed before the winding arrangement is finalized.

Main Technical Specifications

Parameter

Typical range / configuration basis

Rated voltage

Up to 35 kV input typical

Rated capacity

100 kVA-50 MVA

Frequency

50 Hz or 60 Hz; utility-specific where applicable

Standards basis

IEC 61378 and project requirements

Electrical duty

Voltage ratio, load waveform, harmonics and duty cycle confirmed per application

Construction

Oil-immersed, dry-type or protected enclosure according to service conditions

Protection

Temperature, overcurrent and application-specific protection interfaces

Documentation

Approved drawings, data sheets and agreed inspection/test records

Application-Specific Design

Special transformer design begins with the actual load rather than a standard catalogue value. Harmonics, pulse number, isolation duty, overload cycle, enclosure and regulatory requirements determine the winding arrangement and thermal design.

  • Six-, twelve- or multi-pulse arrangements.
  • phase-shifting windings.
  • interphase options.
  • oil-immersed or dry-type construction.

Main Applications

Electrolysis, metal processing, industrial drives and rectifier systems.

  • Process-industry and rectifier loads.
  • Electrical isolation and sensitive equipment.
  • Mining and hazardous-location power distribution.

Engineering Support

Apex supports requirement review, product selection, drawing and interface coordination, manufacturing follow-up, inspection/test-document coordination, export packing and delivery planning. The final scope is defined in the quotation and approved technical agreement.

Recommended Products

Industrial Isolation Transformer | Mining Explosion-Proof Transformer | KYN28 Metal-Clad MV Switchgear