Oil Immersed Power Transformer | Outdoor High Capacity Grid Transformer
Our experienced international trade team is dedicated to providing customers worldwide with high-quality transformers and power transmission products that meet international standards.
Backed by CE certification and a commitment to excellence, we continue to expand our footprint, delivering reliable power solutions to clients worldwide.
20+ exporting
Empowering customers with high-end electrical products and premium solutions. To be a trusted and innovative leader in power products and solutions worldwide. Pioneering intelligent electrical ecosystems that are reliable, efficient, and Eco-friendly.
Quick Response
With extensive experience in global collaboration, our team responds promptly to your needs — saving time and achieving mutual success.
Ownership & Responsibility
“At this moment, it’s up to me.”When challenges arise, our team members step forward, take responsibility, and see every issue through to resolution.
Commercial Power Transformer | Shopping Mall Office Building Transformer
Energy saving power transformer adopts high permeability core, effectively reducing no-load loss. Eco-friendly design to cut long-term power operation cost.
Frequently Asked Questions (FAQ)
Q:What services do you provide?
A:We provide comprehensive end-to-end solutions and services, covering the entire process from electrical and mechanical design, quality control, material selection, core processing, winding, assembly, insulation, and testing to packaging.
Q:What are the handling methods for oil leakage in the high-voltage bushing of a transformer?
A:Minor leakage: Tighten the flange bolts of the casing and replace the sealing gasket; Severe leakage: Replace the casing after power outage; If the insulation inside the casing gets damp, conduct an insulation test and replace the casing if necessary.
Q:What are the reasons for excessive noise when the transformer is operating? How can the noise be reduced?
A:Reasons: Loosening of core, deformation of windings, resonance of components, failure of cooling system, influence of grid harmonics. Measures: Tighten the core clamps; Correct the position of windings; Adjust the shock absorption devices of cooling fans / oil pumps; Install soundproof covers; Address grid harmonics.
Q:What issues should be noted when connecting the transformer to the distribution cabinet?
A:Use copper busbars or cables for connection, with the conductor cross-section meeting the current-carrying requirements; the connection points need to be treated with tin plating or silver plating to reduce contact resistance; install lightning arresters and disconnect switches on the high-voltage side to facilitate maintenance; add insulating covers for the busbars on the low-voltage side and mark the phase sequence; after connection, check the insulation and phase sequence to ensure there are no errors.